문서 작성 : CSU 최재혁 # luxadm prob <- 엔클르주 네임 확인 Found Enclosure: SUNWGS INT FCBPL Name:FCloop Node WWN:508002000017ced0 Logical Path:/dev/es/ses0 Found Fibre Channel device: Node WWN:50020f200000b55e Device Type:Disk device Logical Path:/dev/rdsk/c1t1d0s2 # luxadm disp FCloop <- 디스크 슬롯확인 SUNWGS INT FCBPL DISK STATUS SLOT DISKS (Node WWN) 0 On (O.K.) 20000004cf3b81bf 1 On (O.K.) 20000004cf207d09 2 On (O.K.) 20000004cf20bfa3 3 On (O.K.) 20000004cf20eca7 4 On (O.K.) 20000004cf20853f 5 On (O.K.) 20000004cf20c90e 6 On (Login failed) 7 On (Login failed) 8 On (Login failed) 9 On (Login failed) 10 On (Login failed) 11 On (Login failed) SUBSYSTEM STATUS FW Revision:9224 Box ID:0 Node WWN:508002000017ced0 Enclosure Name:FCloop SSC100's - 0=Base Bkpln, 1=Base LoopB, 2=Exp Bkpln, 3=Exp LoopB SSC100 #0: O.K.(9224/ 3FA5) SSC100 #1: O.K.(9224/ 3FA5) SSC100 #2: Not Installed SSC100 #3: Not Installed Temperature Sensors - 0 Base, 1 Expansion 0:23튏 1Not Installed Default Language is USA English, ASCII == 만약 0번디스크가 장애 났을 경우 # luxadm remove_device FCloop,s0 Device DISK10 removed Drive in Box Name "FCloop" slot 0 Logical Nodes being removed under /dev/dsk/ and /dev/rdsk: Logical Nodes being removed under /dev/dsk/ and /dev/rdsk: c1t12d0s0 c1t12d0s1 c1t12d0s2 c1t12d0s3 c1t12d0s4 c1t12d0s5 c1t12d0s6 c1t12d0s7 # luxadm insert_device FCloop,s0 The list of devices which will be inserted is: 1: Box Name "FCloop" front slot 0 Please enter 'q' to Quit or <Return> to Continue: Hit <Return> after inserting the device(s). == 물리적 디스크교체 후 엔터 ==== |
V880에서 디스크 교체
2006. 10. 10. 13:46